1) Open the folder < Cummins InSite 8.2.0 install>
2) open the autorun.exe
3) Here is Insite installation menu
4) go to manually install packages
5) install 8.2.0
6) go to upgrade insite on the dvd menu
7) let update manager find the updates off the dvd
which will update it just below sp5
change dropdown un update manager to find updates off internet and let it completely update
I think 7.6.1 has been removed off their site and 7.6.2 needs it
9) disable your antivirus program
10) Open the folder Cummins insite 7.x keygen (Cummins 7.x kg)
11) insert your PC-ID and get key for activation
12) .insert the activation key to run the software
Here you go… How to solve Cummins Insite 8.1 Connection Error 5204 5202 5201 5200
with DPA5 adapter, i try to connect with Cummins insite and i have error code 5204 or only no connection and not blinking the leds
This is the error 5204 popped up when connect Prostar 2005 with cummins engine:
ECM connection
Error number: 5204
Communication between the datalink adapter and the ECM could not be established.
Please check the following conditions:
The key switch is on
The cables are between the datalink and the ECM are properly connected
The cables are in good condition
The correct adapteunication protocol is selected
r type is selected
The correct comm
Select retry, cancel or help for additional troubleshooting steps
Here is what have been tried but failed!
Try to connect whit J1939…..same issue
On truck does not even get the engine and the others only couple line and very slow, might be some thing with them trucks
some things odd2006 models connect through J1939 and works.
Tryed on 3 trucks already that are 2005 and older the connect thought J1708 it says engine 128
And when doing the J 1939 test on them it says something like data error
Check the driver is installed well
J1939 & J1708 are added to the software
Finally, SOLVED!
The solution is this, connect, then scan to diagnostic connector but not to USB, open the Cummins insite and push connect, when the Insite begin to connect, immediately connect the USB and ready….
The final tip- Error Messages for communication failures:
Error 5200: Indicates communication loss between computer and the datalink
adapter.Error 5201: Indicates communication loss between the datalink adapter and the
Error 5202: Indicates no communication could be established between the
ECM.
datalink adapter and the computer.
Error 5204: Indicates no communication could be established between the
datalink adapter and the ECM.
If the “Auto Configure” and/or “Datalink Adapter Connection Test” do not find the adapter when connected, manually configure the Cummins Inline 6 Data link adapter connection.
http://www.obd2eshop.com/wholesale/cummins-inline-6-plus-cummins-insite-software-pro-version.html
Here share with you a working solution for Cummins INSITE 8.2.0 registration error “Your registration information is incorrect”. So you can activate Cummins INSITE successfully!
Error: After I installed Cummins INSITE 8.2.0, I fulfilled all blanks on the registration diaglog, but it popped up a error message saying the registration did not succeeded!
What should I do? Please help!
Solution:
About Cummins INSITE 8.2.0 activation fail problem, check below important tips:
(Tested OK on both Cummins INSITE Pro and Cummins INSITE Lite)
1. Check if you run as Administrator?
2. Check if you install Cummins INSITE drivers properly? Next open and close Cummins INSITE, open it again then complete the activation.
3. Go to “insite360pro Properties”, find “Privilege level” and check the box “Run this program as an administrator” as below:
4. Please do not change any computer setting like Country or Language.
5. Maybe your Windows system is inactivated.
P.S What’s the difference between Cummins INSITE Pro and Cummins INSITE Lite?
Cummins INSITE Pro and Cummins INSITE Lite share almost SAME functions but Cummins INSITE Pro can do additional calibration functions:
Read/Retrieve Calibration Files
Load Engine and Programmable Datalink Device Calibrations
While all other Cummins INSITE versions can’t do that!
But if you mostly want to read DTC and no need to get calibrations, Cummins INSITE Lite is enough.www.obd2eshop.com
Now you need to start to change the date on the computer,
set the date 1 january 2014 on your computer/notebook.
Then run the program INSITE. You will see a message about changing the date. Click OK.
Now you can see the PC-ID and Verificaton Code
for ex. see the picture:
Here you go… How to solve Cummins Insite 8.1 Connection Error 5204 5202 5201 5200
with DPA5 adapter, i try to connect with Cummins insite and i have error code 5204 or only no connection and not blinking the leds
This is the error 5204 popped up when connect Prostar 2005 with cummins engine:
ECM connection
Error number: 5204
Communication between the datalink adapter and the ECM could not be established.
Please check the following conditions:
The key switch is on
The cables are between the datalink and the ECM are properly connected
The cables are in good condition
The correct adapteunication protocol is selected
r type is selected
The correct comm
Select retry, cancel or help for additional troubleshooting steps
Here is what have been tried but failed!
Try to connect whit J1939…..same issue
On truck does not even get the engine and the others only couple line and very slow, might be some thing with them trucks
some things odd2006 models connect through J1939 and works.
Tryed on 3 trucks already that are 2005 and older the connect thought J1708 it says engine 128
And when doing the J 1939 test on them it says something like data error
Check the driver is installed well
J1939 & J1708 are added to the software
Finally, SOLVED!
The solution is this, connect, then scan to diagnostic connector but not to USB, open the Cummins insite and push connect, when the Insite begin to connect, immediately connect the USB and ready….
The final tip- Error Messages for communication failures:
Error 5200: Indicates communication loss between computer and the datalink
adapter.
Error 5201: Indicates communication loss between the datalink adapter and the
ECM.
Error 5202: Indicates no communication could be established between the
datalink adapter and the computer.
Error 5204: Indicates no communication could be established between the
datalink adapter and the ECM.
If the “Auto Configure” and/or “Datalink Adapter Connection Test” do not find the adapter when connected, manually configure the Cummins Inline 6 Data link adapter connection.